Activities of the subcommittee on cathodic protection
Toru Wakabayashi
pp. 113-113
DOI:
10.3323/jcorr.73.113Backnumber
Vol. 73 (2024)
Vol. 72 (2023)
Vol. 71 (2022)
Vol. 70 (2021)
Vol. 69 (2020)
Vol. 68 (2019)
Vol. 67 (2018)
Vol. 66 (2017)
Vol. 65 (2016)
Vol. 64 (2015)
Vol. 63 (2014)
Vol. 62 (2013)
Vol. 61 (2012)
Vol. 60 (2011)
Vol. 59 (2010)
Vol. 58 (2009)
Vol. 57 (2008)
Vol. 56 (2007)
Vol. 55 (2006)
Vol. 54 (2005)
Vol. 53 (2004)
Vol. 52 (2003)
Vol. 51 (2002)
Vol. 50 (2001)
Vol. 49 (2000)
Vol. 48 (1999)
Vol. 47 (1998)
Vol. 46 (1997)
Vol. 45 (1996)
Vol. 44 (1995)
Vol. 43 (1994)
Vol. 42 (1993)
Vol. 41 (1992)
Vol. 40 (1991)
21 Nov. (Last 30 Days)
Toru Wakabayashi
pp. 113-113
DOI:
10.3323/jcorr.73.113Mikio Takemoto, Kiyoko Takeda
pp. 123-133
DOI:
10.3323/jcorr.73.123Abstract
Authors experienced two type damages in the Type-316 stainless steel loading devices which were used for SCC tests in simulated PWR primary water or BWR water. These damages were 1) cracking at the bottom of the commercial rolled thread used in the simulated PWR primary water at 340℃ for 3,000 hours and 2) cracking at the round corner of the cantilever beam type loading device used in the simulated BWR water at 288℃ for 1,000 hours. We observed fracture surfaces of the crackings in the devices and compared them with fracture surfaces in our previous and recent new SCC specimens. The fractographic study revealed that both quasi-cleavage transgranular fracture surface and intergranular surface existed in the device as well the SCC specimens. We therefore postulated that the crackings in the devices were produced by environmental assistance of high temperature water, and not by the mechanical fracture due to materials defects.
Ippei Shinozaki, Tomomi Kouketsu, Takuya Kawarasaki, Yohei Sakakibara
pp. 134-138
DOI:
10.3323/jcorr.73.134Abstract
To investigate the effect of localized repair of anodized film on Aluminum, corrosion resistance of anodized A1050 with re-anodized film using a flow cell was evaluated by CASS testing. The interface between the anodized film and the re-anodized film had a thinner film. It was found that corrosion of the anodized film initiated on this film interface and progressed to the initial anodized film side.
21 Nov. (Last 30 Days)
ISIJ International Advance Publication
ISIJ International Advance Publication
ISIJ International Advance Publication
ISIJ International Vol.64(2024), No.13
Tetsu-to-Hagané Advance Publication
ISIJ International Advance Publication
Tetsu-to-Hagané Advance Publication
Tetsu-to-Hagané Advance Publication
ISIJ International Advance Publication
ISIJ International Advance Publication
You can use this feature after you logged into the site.
Please click the button below.
Please enter the publication date
with Christian era
(4 digits).
Please enter your search criteria.