An Article to the 56th Japan Conference on Materials and Environments in Toyama
Satoshi Sunada
pp. 355-355
DOI:
10.3323/jcorr.67.355Backnumber
Vol. 73 (2024)
Vol. 72 (2023)
Vol. 71 (2022)
Vol. 70 (2021)
Vol. 69 (2020)
Vol. 68 (2019)
Vol. 67 (2018)
Vol. 66 (2017)
Vol. 65 (2016)
Vol. 64 (2015)
Vol. 63 (2014)
Vol. 62 (2013)
Vol. 61 (2012)
Vol. 60 (2011)
Vol. 59 (2010)
Vol. 58 (2009)
Vol. 57 (2008)
Vol. 56 (2007)
Vol. 55 (2006)
Vol. 54 (2005)
Vol. 53 (2004)
Vol. 52 (2003)
Vol. 51 (2002)
Vol. 50 (2001)
Vol. 49 (2000)
Vol. 48 (1999)
Vol. 47 (1998)
Vol. 46 (1997)
Vol. 45 (1996)
Vol. 44 (1995)
Vol. 43 (1994)
Vol. 42 (1993)
Vol. 41 (1992)
Vol. 40 (1991)
21 Nov. (Last 30 Days)
Satoshi Sunada
pp. 355-355
DOI:
10.3323/jcorr.67.355Toshiyasu Nishimura
pp. 356-361
DOI:
10.3323/jcorr.67.356Abstract
The corrosion potential measurement and Electrochemical Impedance Spectroscopy (EIS) are explained for the observation of the corrosion of reinforced steels in concrete. In the case of environment factors in concrete, the measurements for the concentration of chloride ions and pH are applied. Besides, by using the actual concrete block, the corrosion of the steel and environmental factors are measured by these methods, and the meaning of the results are explained. Finally, the electrochemical methods are shown in the application for the actual concrete bridge.
Atsushi Nishikata
pp. 362-367
DOI:
10.3323/jcorr.67.362Abstract
Electrochemical measurement methods for studying metallic corrosion in a simulated soil are described. First of all, the characteristics of soil corrosion are briefly explained, and then the electrochemical cells for studying the soil corrosion in laboratory is illustrated. Finally, some examples of the electrochemical measurements results are shown.
Takumi Haruna, Yuki Miyataki, Youhei Hirohata, Toshio Shibata, Naoki Taniguchi, Hirokazu Tachikawa
pp. 375-380
DOI:
10.3323/jcorr.67.375Abstract
This research aimed to confirm the formation of Fe3O4 film on Fe immersed in aqueous 45 mass% NaOH solution containing some oxidants at the boiling temperature, to recognize the optimum immersion time for the formation of thick and protective film, and to reveal the absorption behavior of D2O in the Fe3O4 film at room temperature. The results were obtained as follows. It was confirmed that Fe3O4 film was formed on Fe immersed in the NaOH solution for a time more than 0.6 ks, and the film thickness increased parabolically with an increase in the immersion time. D2O absorption test was carried out to the films formed in the NaOH solution for immersion times of 1.2 and 3.6 ks. An amount of D2O absorbed into the film increased with an increase in an absorption time up to 1000 ks, and an absorption time more than 1000 ks made an amount of D2O constant. The constant amount of D2O was larger for the film formed on Fe immersed in the NaOH solution for 3.6 ks than that for 1.2 ks. The transient of the amount of D2O absorbed into the film was analyzed on the basis of Fick’s law for diffusion, and diffusion coefficients of D2O were obtained to be 5.1×10-15 and 9.9×10-15 cm2・s-1 for the films formed for 1.2 and 3.6 ks, respectively. Therefore it was estimated that the diffusion coefficient of the Fe3O4 film was in the region from 5.1×10-15 to 9.9×10-15 cm2・s-1.
Readers Who Read This Article Also Read
Zairyo-to-Kankyo Vol.54(2005), No.1
Yasutaka Soma, Atsushi Komatsu, Fumiyoshi Ueno
pp. 381-385
DOI:
10.3323/jcorr.67.381Abstract
In-situ measurement of electrical conductivity of solution within crevice of SUS316L stainless steel in 288℃ water has been conducted with newly developed electrochemical sensor system. The sensor consists of electrode (φ≈ 250μm stainless steel) and insulator (high purity alumina) directory imbedded into crevice former plate. The sensor measures local electrical conductivity of crevice solution beneath the electrode (κcrev) with electrochemical impedance method. The sensors were installed at different positions within tapered crevice of SUS316L stainless steel. The crevice specimen with the sensors were immerged into 288℃, 8 MPa, pure oxygen saturated high purity water for 100 h. κcrev at a position with crevice gap(g) of ≈ 59.3μm was 8~11μS・cm-1, least deviate from conductivity of 288℃ pure water (3.7μS・cm-1) and no localized corrosion occurred. On the contrary, κcrev at a position with g ≈4.4μm increased with time and showed maximum value of ≈1600μS・cm-1 at 70 h. Localized corrosion occurred in the vicinity of this position. Thermodynamic equilibrium calculation based on oxide in the crevice and the maximum κcrev(1600μS・cm-1) showed that pH of crevice solution can be reached to 3.53. It can be concluded that acidification occurred in tight crevice even under high purity bulk water and resulted in localized corrosion.
21 Nov. (Last 30 Days)
ISIJ International Advance Publication
ISIJ International Advance Publication
ISIJ International Advance Publication
ISIJ International Vol.64(2024), No.13
Tetsu-to-Hagané Advance Publication
ISIJ International Advance Publication
Tetsu-to-Hagané Advance Publication
Tetsu-to-Hagané Advance Publication
ISIJ International Advance Publication
ISIJ International Advance Publication
You can use this feature after you logged into the site.
Please click the button below.
Please enter the publication date
with Christian era
(4 digits).
Please enter your search criteria.