Change with the Times
Kiyoko Takeda
pp. 437-437
DOI:
10.3323/jcorr.67.437Readers Who Read This Article Also Read
Zairyo-to-Kankyo Vol.67(2018), No.11
Backnumber
Vol. 73 (2024)
Vol. 72 (2023)
Vol. 71 (2022)
Vol. 70 (2021)
Vol. 69 (2020)
Vol. 68 (2019)
Vol. 67 (2018)
Vol. 66 (2017)
Vol. 65 (2016)
Vol. 64 (2015)
Vol. 63 (2014)
Vol. 62 (2013)
Vol. 61 (2012)
Vol. 60 (2011)
Vol. 59 (2010)
Vol. 58 (2009)
Vol. 57 (2008)
Vol. 56 (2007)
Vol. 55 (2006)
Vol. 54 (2005)
Vol. 53 (2004)
Vol. 52 (2003)
Vol. 51 (2002)
Vol. 50 (2001)
Vol. 49 (2000)
Vol. 48 (1999)
Vol. 47 (1998)
Vol. 46 (1997)
Vol. 45 (1996)
Vol. 44 (1995)
Vol. 43 (1994)
Vol. 42 (1993)
Vol. 41 (1992)
Vol. 40 (1991)
21 Nov. (Last 30 Days)
Kiyoko Takeda
pp. 437-437
DOI:
10.3323/jcorr.67.437Readers Who Read This Article Also Read
Zairyo-to-Kankyo Vol.67(2018), No.11
Hitoshi Yashiro
pp. 438-441
DOI:
10.3323/jcorr.67.438Abstract
In this article, introductory explanation for electrochemical measurements in high temperature aqueous solutions is presented. Although basics are common to normal electrochemistry at ambient temperatures, special attention is required to a reference electrode in an autoclave system because measured potential should be presented with respect to standard hydrogen electrode at given temperature. Two typical reference electrode systems, i.e. internal and external silver-silver chloride electrodes are explained in detail. Some examples of polarization measurements are also introduced.
Ryo Ishibashi, Koji Fujimoto, Chiaki Kato, Yuichi Miyahara, Kenji Kako, Kiyoko Takeda, Yohei Sakakibara, Yutaka Watanabe
pp. 442-449
DOI:
10.3323/jcorr.67.442Abstract
Because of lack of test standards applicable in high-purity water at high temperatures, standardization of test methods for evaluating the stress corrosion cracking initiation of metals and alloys used for nuclear power plant has been carried out. The standard of uniaxial constant load test method has been established and stipulated in JSCE standard (JSCE S 1501). The Japan industry standard (JIS G 0511) has been reviewed and modified for the rationalization of reverse U-bend test method. Furthermore, the attempt to reflect these discussed technical resolutions in ISO standard is currently ongoing.
Hiroyuki Abe, Akio Yasukawa, Rintaro Minamitani, Hiroyuki Saito
pp. 453-456
DOI:
10.3323/jcorr.67.453Abstract
We studied S8 gas analysis method of S8 gas released from sulfur vulcanized rubber duct installed in the engine room of vehicles. GC-MS and HPLC were used for gas analysis. As a result, HPLC could detect S8 gas quantitatively. On the other hand, GC-MS failed to detect S8 gas, because S8 gas was trapped in the column and thus could not reach the mass spectrometer.
Md. Saiful Islam, Kyohei Otani, Masatoshi Sakairi
pp. 457-461
DOI:
10.3323/jcorr.67.457Abstract
The influence of metal cations on corrosion of mild steel sheet was investigated by immersion tests and electrochemical impedance spectroscopy( EIS) at high temperature using solutions of simulated fresh water. Immersion tests showed the different corrosion rates in different solutions, and the steel showed the minimum corrosion in the solution containing Zn2+. Surface morphology changes of steel due to corrosion by the metal cations were carried out by scanning electron microscopy (SEM). Measurement of the charge transfer resistance (Rct) and XPS results suggested that Zn2+ exists on the steel surface by forming a layer, thereby improving the protective property of the passive films of mild steel.
Kunitsugu Aramaki
pp. 462-465
DOI:
10.3323/jcorr.67.462Abstract
Decamethyleneimine(CH2)10 NH has been proposed to be an effective inhibitor due to a π-characterized unshared pair of electrons on the N atom deformed by strain in the ring to near 120° of C-N-C bond angle. It is concluded in this paper that the N atom in the sp2 hybrid orbital geometry is classified as a soft base and the bare iron surface belongs to a soft acid, resulting in the formation of a stable chemisorption bond and hence, in the enhanced inhibition efficiency.
Shigenobu Kainuma, Gaku Mashimoto, Muye Yang, Takao Sajima
pp. 466-473
DOI:
10.3323/jcorr.67.466Abstract
The corrosion would often progress with the mutual interaction between adjacent defects, especially at some locations of paint-coated steel structures where the rainwater or dew stagnated in long-term, because of the occurrence of electrical short circuit around the multiple coating defects.The objective of this study is to investigate the electrochemical mechanism of mutual interaction between the adjacent coating defects in a stagnant water environment. The model specimens embedded with a plurality of electrodes were fabricated to simulate coating defects, and the corrosion currents were measured between these electrodes. In case of the two electrodes with different diameters, the measurement results show that the anode reaction would be fixed in the electrode with a relative larger diameter, while the cathode reaction would be fixed in the electrode with a small diameter. In addition, when the diameter of the electrode is less than 20 mm, it has been clarified that the linear correlation exists between the area ratio of adjacent electrodes and the macrocell current density, and the relationship was formulated.
Readers Who Read This Article Also Read
Zairyo-to-Kankyo Vol.67(2018), No.11
21 Nov. (Last 30 Days)
ISIJ International Advance Publication
ISIJ International Advance Publication
ISIJ International Advance Publication
ISIJ International Vol.64(2024), No.13
Tetsu-to-Hagané Advance Publication
ISIJ International Advance Publication
Tetsu-to-Hagané Advance Publication
Tetsu-to-Hagané Advance Publication
ISIJ International Advance Publication
ISIJ International Advance Publication
You can use this feature after you logged into the site.
Please click the button below.
Please enter the publication date
with Christian era
(4 digits).
Please enter your search criteria.