論文検索サイト

材料と環境 Vol. 67 (2018), No. 9

ISIJ International
belloff
オンライン版ISSN: 1881-9664
冊子版ISSN: 0917-0480
発行機関: Japan Society of Corrosion Engineering

Backnumber

  1. Vol. 73 (2024)

  2. Vol. 72 (2023)

  3. Vol. 71 (2022)

  4. Vol. 70 (2021)

  5. Vol. 69 (2020)

  6. Vol. 68 (2019)

  7. Vol. 67 (2018)

  8. Vol. 66 (2017)

  9. Vol. 65 (2016)

  10. Vol. 64 (2015)

  11. Vol. 63 (2014)

  12. Vol. 62 (2013)

  13. Vol. 61 (2012)

  14. Vol. 60 (2011)

  15. Vol. 59 (2010)

  16. Vol. 58 (2009)

  17. Vol. 57 (2008)

  18. Vol. 56 (2007)

  19. Vol. 55 (2006)

  20. Vol. 54 (2005)

  21. Vol. 53 (2004)

  22. Vol. 52 (2003)

  23. Vol. 51 (2002)

  24. Vol. 50 (2001)

  25. Vol. 49 (2000)

  26. Vol. 48 (1999)

  27. Vol. 47 (1998)

  28. Vol. 46 (1997)

  29. Vol. 45 (1996)

  30. Vol. 44 (1995)

  31. Vol. 43 (1994)

  32. Vol. 42 (1993)

  33. Vol. 41 (1992)

  34. Vol. 40 (1991)

材料と環境 Vol. 67 (2018), No. 9

Ⅳ.各種環境での電気化学測定―コンクリート―

西村 俊弥

pp. 356-361

抄録

The corrosion potential measurement and Electrochemical Impedance Spectroscopy (EIS) are explained for the observation of the corrosion of reinforced steels in concrete. In the case of environment factors in concrete, the measurements for the concentration of chloride ions and pH are applied. Besides, by using the actual concrete block, the corrosion of the steel and environmental factors are measured by these methods, and the meaning of the results are explained. Finally, the electrochemical methods are shown in the application for the actual concrete bridge.

ブックマーク

SNSによる共有

論文タイトル

Ⅳ.各種環境での電気化学測定―コンクリート―

Ⅳ.各種環境での電気化学測定―土壌環境―

西方 篤

pp. 362-367

抄録

Electrochemical measurement methods for studying metallic corrosion in a simulated soil are described. First of all, the characteristics of soil corrosion are briefly explained, and then the electrochemical cells for studying the soil corrosion in laboratory is illustrated. Finally, some examples of the electrochemical measurements results are shown.

ブックマーク

SNSによる共有

論文タイトル

Ⅳ.各種環境での電気化学測定―土壌環境―

酸化剤含有NaOH水溶液中でFeに形成させたFe3O4皮膜中へのD2Oの拡散浸透挙動

春名 匠, 宮瀧 裕貴, 廣畑 洋平, 柴田 俊夫, 谷口 直樹, 立川 博一

pp. 375-380

抄録

This research aimed to confirm the formation of Fe3O4 film on Fe immersed in aqueous 45 mass% NaOH solution containing some oxidants at the boiling temperature, to recognize the optimum immersion time for the formation of thick and protective film, and to reveal the absorption behavior of D2O in the Fe3O4 film at room temperature. The results were obtained as follows. It was confirmed that Fe3O4 film was formed on Fe immersed in the NaOH solution for a time more than 0.6 ks, and the film thickness increased parabolically with an increase in the immersion time. D2O absorption test was carried out to the films formed in the NaOH solution for immersion times of 1.2 and 3.6 ks. An amount of D2O absorbed into the film increased with an increase in an absorption time up to 1000 ks, and an absorption time more than 1000 ks made an amount of D2O constant. The constant amount of D2O was larger for the film formed on Fe immersed in the NaOH solution for 3.6 ks than that for 1.2 ks. The transient of the amount of D2O absorbed into the film was analyzed on the basis of Fick’s law for diffusion, and diffusion coefficients of D2O were obtained to be 5.1×10-15 and 9.9×10-15 cm2・s-1 for the films formed for 1.2 and 3.6 ks, respectively. Therefore it was estimated that the diffusion coefficient of the Fe3O4 film was in the region from 5.1×10-15 to 9.9×10-15 cm2・s-1.

他の人はこちらも検索

ブックマーク

SNSによる共有

論文タイトル

酸化剤含有NaOH水溶液中でFeに形成させたFe3O4皮膜中へのD2Oの拡散浸透挙動

高温高純度水中におけるステンレス鋼のすき間内溶液導電率のIn-situ分析

相馬 康孝, 小松 篤史, 上野 文義

pp. 381-385

抄録

In-situ measurement of electrical conductivity of solution within crevice of SUS316L stainless steel in 288℃ water has been conducted with newly developed electrochemical sensor system. The sensor consists of electrode (φ≈ 250μm stainless steel) and insulator (high purity alumina) directory imbedded into crevice former plate. The sensor measures local electrical conductivity of crevice solution beneath the electrode (κcrev) with electrochemical impedance method. The sensors were installed at different positions within tapered crevice of SUS316L stainless steel. The crevice specimen with the sensors were immerged into 288℃, 8 MPa, pure oxygen saturated high purity water for 100 h. κcrev at a position with crevice gap(g) of ≈ 59.3μm was 8~11μS・cm-1, least deviate from conductivity of 288℃ pure water (3.7μS・cm-1) and no localized corrosion occurred. On the contrary, κcrev at a position with g ≈4.4μm increased with time and showed maximum value of ≈1600μS・cm-1 at 70 h. Localized corrosion occurred in the vicinity of this position. Thermodynamic equilibrium calculation based on oxide in the crevice and the maximum κcrev(1600μS・cm-1) showed that pH of crevice solution can be reached to 3.53. It can be concluded that acidification occurred in tight crevice even under high purity bulk water and resulted in localized corrosion.

ブックマーク

SNSによる共有

論文タイトル

高温高純度水中におけるステンレス鋼のすき間内溶液導電率のIn-situ分析

この機能はログイン後に利用できます。
下のボタンをクリックしてください。

詳細検索

論文タイトル

著者

抄録

ジャーナル名

出版日を西暦で入力してください(4桁の数字)。

検索したいキーワードを入力して下さい