材料と環境 Vol. 69 (2020), No. 3
石油タンク底板内面に施工される重防食コーティングの深さ方向分析に基づいた等価回路モデル適用とその有効性
徳武 皓也, 岡崎 慎司, 佐々木 翔平
pp. 66-72
DOI:
10.3323/jcorr.69.66抄録
To investigating the long-term degradation of a heavy-duty coating, Fourier transform infrared spectroscopy (FT-IR) and Raman spectroscopy along the depth direction of a vinyl ester resin organic coating containing glass flakes was conducted. The organic coating sample was applied to the inner surface of the bottom plate of the oil storage tank, and used for approximately seventeen years. In addition, the degradation evaluation using the electrical equivalent circuit (EEC) model considering depth direction distribution of R//C time-constant (Voigt measurement model) was examined in detail.In the FT-IR along the coating depth direction, no clear peak shift and/or disappearance of the spectrum was observed. On the other hand, the baseline of the Raman shift of the coating gradually increased from near the steel substrate interface toward coating surface. These results suggest that the long-term coating degradation appears as a difference in physical change along the depth direction, and supports the result that the impedance characteristics of the coating can be well-analyzed by Voigt measurement model. Furthermore, it is expected that the DC resistance value can be estimated accurately by the EEC analysis using Voigt measurement model.
鋼材表面に生成した腐食生成物の機械学習による放射光XAFS解析
小澤 敬祐, 山本 慎太郎, 森 拓弥, 横溝 臣智, 李 雷, 横山 和司, 春名 匠
pp. 73-76
DOI:
10.3323/jcorr.69.73抄録
The rust layer changing behavior of initial corrosion on carbon steel was investigated by XAFS analysis using the large synchrotron radiation. Analysis of XANES spectrum and RDF by machine learning showed that the change in valence state and Fe-O covalent bond distance corresponded well with the initial corrosion rate. The distribution of valence and Fe-O bond distance of corrosion products on the steel surface showed a different tendency. These results suggest that the combination of synchrotron radiation analysis and machine learning is effective for elucidating rust formation mechanisms in initial corrosion.
他の人はこちらも検索
MATERIALS TRANSACTIONS Vol.57(2016), No.1
ISIJ International Vol.55(2015), No.8
材料と環境 Vol.69(2020), No.3
田園地帯における44年曝露後の耐候性鋼のさび層の解析
佐藤 妃奈, 長澤 慎, 金子 道郎, 壱岐 浩
pp. 77-82
DOI:
10.3323/jcorr.69.77抄録
Protective rust formed on Cr-Cu-Ni-P and Cr-Cu weathering steels (WSs) exposed for 44 years were analyzed to compare with previous studies for exposure test results for weathering steels. The formation of a typical protective rust composed of a polarizing layer (crystalline α-FeOOH and γ-FeOOH) and an insulation layer (fine α-FeOOH) was observed on both the weathering steels. Alloy elements were distributed in the protective rust layer. Cr enrichment was observed in the insulation layer. It was similar to previous studies and indicated that Cr contributed to form fine rust. Cu was present in the insulation layer, P was present in the insulation layer and the top of the polarizing layer, and Ni was present in the entire rust layer. Structure of the rust layers and the distribution of Cr and Ni were consistent in the results of previous studies, the exposure tests for less than 32 years, however there was a difference in the distribution of Cu and P.
他の人はこちらも検索
材料と環境 Vol.53(2004), No.1
材料と環境 Vol.57(2008), No.2
材料と環境 Vol.64(2015), No.7
温水環境における銅管のⅡ型孔食再現の試みと塩化物イオン濃度の影響について
大工原 毅, 五味 保城, 中里 直人, 境 昌宏
pp. 83-89
DOI:
10.3323/jcorr.69.83抄録
In order to clarify the corrosion resistance of copper tube in which 80℃ hot water flows, pitting production test by constant potential polarization was attempted and pitting potential was measured. In case of pre-coated specimen and under the condition that the test water was flowing, pitting corrosion occurred. And pitting potential was present between 190 mV vs.SSE and 210 mV vs.SSE, when the chloride ion concentration is 10 mg/L to 100 mg/L.
論文アクセスランキング
21 Dec. (Last 30 Days)
-
Wettability of CaS against molten iron at 1873 K
ISIJ International 早期公開
-
凝固過程における溶鋼中からAl2O3上へのMnSの晶出挙動
鉄と鋼 早期公開
-
-
In-situ Observation of Precipitation and Growth of MnS Inclusions during Solidification of a High Sulfur Steel
ISIJ International Vol.64(2024), No.14
-
-
モデル材料を用いた凝固過程における介在物生成挙動のその場観察
鉄と鋼 早期公開
-
Transition behavior of gas containing suspension from solid-like to liquid-like flows
ISIJ International 早期公開
-
-
Slag-steel reactions in the refining of Advanced High-Strength Steel
ISIJ International 早期公開
-
Chemical and Mechanical Factors on Phosphorus Dissolution Behavior from P-concentrated Slag
ISIJ International Vol.64(2024), No.14
この機能はログイン後に利用できます。
下のボタンをクリックしてください。