論文検索サイト

材料と環境 Vol. 56 (2007), No. 4

ISIJ International
belloff
オンライン版ISSN: 1881-9664
冊子版ISSN: 0917-0480
発行機関: Japan Society of Corrosion Engineering

Backnumber

  1. Vol. 73 (2024)

  2. Vol. 72 (2023)

  3. Vol. 71 (2022)

  4. Vol. 70 (2021)

  5. Vol. 69 (2020)

  6. Vol. 68 (2019)

  7. Vol. 67 (2018)

  8. Vol. 66 (2017)

  9. Vol. 65 (2016)

  10. Vol. 64 (2015)

  11. Vol. 63 (2014)

  12. Vol. 62 (2013)

  13. Vol. 61 (2012)

  14. Vol. 60 (2011)

  15. Vol. 59 (2010)

  16. Vol. 58 (2009)

  17. Vol. 57 (2008)

  18. Vol. 56 (2007)

  19. Vol. 55 (2006)

  20. Vol. 54 (2005)

  21. Vol. 53 (2004)

  22. Vol. 52 (2003)

  23. Vol. 51 (2002)

  24. Vol. 50 (2001)

  25. Vol. 49 (2000)

  26. Vol. 48 (1999)

  27. Vol. 47 (1998)

  28. Vol. 46 (1997)

  29. Vol. 45 (1996)

  30. Vol. 44 (1995)

  31. Vol. 43 (1994)

  32. Vol. 42 (1993)

  33. Vol. 41 (1992)

  34. Vol. 40 (1991)

材料と環境 Vol. 56 (2007), No. 4

水素が関与する破壊の特徴

南雲 道彦

pp. 132-147

抄録

Characteristics of hydrogen-related failure are reviewed from mostly experimentally observed features. Comparison with the failure under normal atmospheres is made so as to extract the way by which hydrogen plays a role in the fracture process. Fractographic features associated with plasticity and the promotion of the crack initiation and growth analyzed by means of an R-curve method are presented. Enhanced plastic instability is noted as a precursor of the failure. Effects of hydrogen on stress relaxation and creep are presented as the dislocation dynamics that operate on delayed fracture. Effects of environmental variation of applied stress and external hydrogen potential are also presented.

ブックマーク

SNSによる共有

論文タイトル

水素が関与する破壊の特徴

低炭素鋼の海塩粒子による腐食に及ぼす相対湿度の役割

升田 博之, 片山 英樹

pp. 154-157

抄録

We have developed a new atmospheric corrosion test device that can control the deposition rate of sea salt particles. By using this device, certain amount of seasalt particles were attached on the low alloy steel and the progress of atmospheric corrosion was observed by both the super Kelvin force microscope and Kelvin force microscope under various relative humidity conditions. The results showed that thin liquid film was formed around the corrosion part when corrosion occurred at high relative humidity. After the specimen surface was covered with thin liquid film, Cl ion can move to the corroding part to increase the corrosion rate.

ブックマーク

SNSによる共有

論文タイトル

低炭素鋼の海塩粒子による腐食に及ぼす相対湿度の役割

吸収式冷凍機における腐食生成物の除去回収技術

町澤 健司, 竹中 浩一, 平田 陽一, 長尾 雅志, 大中 紀之, 板垣 昌幸

pp. 158-164

抄録

The techniques have been developed on removal of copper ion in the absorption refrigerator. Results are summarized as follows ;
(1) Concentrations and chemical forms on copper ion and oxides in refrigerant and LiBr solutions in operating refrigerators were analyzed to be base data for removal techniques.
(2) Examining removal technique by electrochemical reducing process, it was clarified that copper ion was effectively reduced to metallic state at the cathode potentials between −1.0∼−0.6 V vs. SSE.
(3) Trial device has been made for removal of copper ion by 2 electrodes system. In the field test, it was clarified that copper ions in both refrigerant and LiBr solution were well collected on the cathode electrode to the concentration levels below the target value of 1 mg dm−3.
(4) A filter device combined with active metal electrodes has been developed for removal of copper ions. Applying the developed unit to laboratory and field tests, it was verified that copper ions in both refrigerant and LiBr solution were well captured to the concentration levels below the target value.

ブックマーク

SNSによる共有

論文タイトル

吸収式冷凍機における腐食生成物の除去回収技術

化学洗浄による吸収式冷凍機の性能回復技術

町澤 健司, 竹中 浩一, 平田 陽一, 小杉 羊一, 大中 紀之, 板垣 昌幸

pp. 165-169

抄録

After long term usage, troubles have been experienced recently such as lowering operation efficiency by plugging of spray nozzles with corrosion products in absorption refrigerator. To solve these problems, removal techniques of plugging by chemical cleaning have been investigated. The following conclusions were obtained:
(1) Chemical cleaning solution of HCl with L-ascorbic acid was developed well designed to have high removal performance on Fe oxide deposit without any damage on copper tubes.
(2) Applying the developed chemical cleaning solution to operating absorption refrigerator, it was proved that the plugging of spray nozzle by oxides was removed giving good operation efficiencies up to 85% from lower lebels of 30 %.
(3) It was also clarified that no damages were observed on copper tubes with the developed chemical cleaning solution.

ブックマーク

SNSによる共有

論文タイトル

化学洗浄による吸収式冷凍機の性能回復技術

銅管のろう付け部における異種金属接触腐食

山手 利博

pp. 170-174

抄録

On the brazing part of copper tube and U bend in the fan coil unit, the solder was not corroded, and the soft copper tube that touches the solder has been corroded one-sidedly. Natural electrode potential of the solder and natural electrode potential of copper were measured on an unused brazing part sample in the tap water. The potential of the solder was about 100 mV higher than the potential of copper. It is guessed that the cause of corrosion is a bimetallic corrosion of which the solder is cathode and copper is anode.