第66回材料と環境討論会
安住 和久
pp. 233-234
DOI:
10.3323/jcorr.68.233他の人はこちらも検索
日本エネルギー学会誌 Vol.99(2020), No.2
鉄と鋼 Vol.61(1975), No.13
鉄と鋼 Vol.61(1975), No.13
ジャーナル
Backnumber
Vol. 73 (2024)
Vol. 72 (2023)
Vol. 71 (2022)
Vol. 70 (2021)
Vol. 69 (2020)
Vol. 68 (2019)
Vol. 67 (2018)
Vol. 66 (2017)
Vol. 65 (2016)
Vol. 64 (2015)
Vol. 63 (2014)
Vol. 62 (2013)
Vol. 61 (2012)
Vol. 60 (2011)
Vol. 59 (2010)
Vol. 58 (2009)
Vol. 57 (2008)
Vol. 56 (2007)
Vol. 55 (2006)
Vol. 54 (2005)
Vol. 53 (2004)
Vol. 52 (2003)
Vol. 51 (2002)
Vol. 50 (2001)
Vol. 49 (2000)
Vol. 48 (1999)
Vol. 47 (1998)
Vol. 46 (1997)
Vol. 45 (1996)
Vol. 44 (1995)
Vol. 43 (1994)
Vol. 42 (1993)
Vol. 41 (1992)
Vol. 40 (1991)
21 Dec. (Last 30 Days)
安住 和久
pp. 233-234
DOI:
10.3323/jcorr.68.233他の人はこちらも検索
日本エネルギー学会誌 Vol.99(2020), No.2
鉄と鋼 Vol.61(1975), No.13
鉄と鋼 Vol.61(1975), No.13
笠原 茂樹, 知見 康弘, 端 邦樹, 塙 悟史
pp. 240-247
DOI:
10.3323/jcorr.68.240抄録
In order to study enivironmentally-assisted cracking mechanism of stainless steel under BWR primary coolant condition, effects of applied load on oxidation in the vicinity of crack tips of CT specimens were evaluated. Loaded CT specimens were immersed in an aqueous condition at 290℃ as a simulated BWR coolant condition, and microstructural observation on oxide near the tips of pre-cracks was carried out. Oxide inner layers, which consisted of fine grain magnetite containing Fe and Cr were formed, and oxide outer layers consisting of large grains of Fe3O4 were observed to cover the inner layers. FEM analysis of stress and strain in the loaded CT specimen suggests that both of dislocations due to localized plastic deformation and elastic strain could play important roles to accelerate inner oxide formation in the vicinity of the crack tip of the specimens.
世利 修美, 今泉 美津徳
pp. 248-254
DOI:
10.3323/jcorr.68.248抄録
Corrosion of metal cans was examined from the viewpoint of polarization resistance. The relationship between results obtained electrochemically using polarization resistance and judgments from empirical can pack test observations was revealed. After practical experiments using actual can container filled with test solutions changing concentrations of chloride ion and hydrogen ions, both results exactly corresponded. It is discussed that the application of polarization resistance to the traditional can pack test will be a very advantageous tool for easy and rapid determination of can degradation.
他の人はこちらも検索
ISIJ International Vol.35(1995), No.12
ISIJ International Vol.60(2020), No.6
21 Dec. (Last 30 Days)
ISIJ International 早期公開
鉄と鋼 早期公開
ISIJ International Vol.64(2024), No.14
鉄と鋼 早期公開
ISIJ International 早期公開
ISIJ International 早期公開
ISIJ International Vol.64(2024), No.14
この機能はログイン後に利用できます。
下のボタンをクリックしてください。
出版日を西暦で入力してください(4桁の数字)。
検索したいキーワードを入力して下さい