論文検索サイト

材料と環境 Vol. 67 (2018), No. 12

ISIJ International
belloff
オンライン版ISSN: 1881-9664
冊子版ISSN: 0917-0480
発行機関: Japan Society of Corrosion Engineering

Backnumber

  1. Vol. 73 (2024)

  2. Vol. 72 (2023)

  3. Vol. 71 (2022)

  4. Vol. 70 (2021)

  5. Vol. 69 (2020)

  6. Vol. 68 (2019)

  7. Vol. 67 (2018)

  8. Vol. 66 (2017)

  9. Vol. 65 (2016)

  10. Vol. 64 (2015)

  11. Vol. 63 (2014)

  12. Vol. 62 (2013)

  13. Vol. 61 (2012)

  14. Vol. 60 (2011)

  15. Vol. 59 (2010)

  16. Vol. 58 (2009)

  17. Vol. 57 (2008)

  18. Vol. 56 (2007)

  19. Vol. 55 (2006)

  20. Vol. 54 (2005)

  21. Vol. 53 (2004)

  22. Vol. 52 (2003)

  23. Vol. 51 (2002)

  24. Vol. 50 (2001)

  25. Vol. 49 (2000)

  26. Vol. 48 (1999)

  27. Vol. 47 (1998)

  28. Vol. 46 (1997)

  29. Vol. 45 (1996)

  30. Vol. 44 (1995)

  31. Vol. 43 (1994)

  32. Vol. 42 (1993)

  33. Vol. 41 (1992)

  34. Vol. 40 (1991)

材料と環境 Vol. 67 (2018), No. 12

Ⅳ.各種環境での電気化学測定―生体用金属材料における電気化学測定―

廣本 祥子

pp. 479-486

抄録

Electrochemical measurements such as polarization and impedance tests are used to evaluate the corrosion resistance of metallic biomaterials. The effect of in vivo biochemical and mechanical corrosion factors on the corrosion behavior of metallic biomaterials and the interaction between metal surface and cells are also examined with the electrochemical techniques. The findings will contribute to improve the corrosion resistance and biocompatibility of conventional and new metallic biomaterials including biodegradable metallic materials. The electrochemical techniques which are used to evaluate and to understand the effect of typical in vivo corrosion factors are introduced.

ブックマーク

SNSによる共有

論文タイトル

Ⅳ.各種環境での電気化学測定―生体用金属材料における電気化学測定―

Ⅳ.各種環境での電気化学測定―原子力Ⅱ(地層処分)深部地下環境における炭素鋼の腐食モニタリング―

谷口 直樹, 中山 雅

pp. 487-494

抄録

This article describes the current status of corrosion monitoring methods and examples of the measurement under deep underground environments for carbon steel overpacks for high-level radioactive waste disposal. Based on the studies on corrosion monitoring using AC Impedance technique, some of the typical measurement systems such as the electrodes arrangement are introduced. In-situ corrosion monitoring in engineering scale test is also being attempted using a deep underground research laboratory, and the measurement method and results are presented in this article.

ブックマーク

SNSによる共有

論文タイトル

Ⅳ.各種環境での電気化学測定―原子力Ⅱ(地層処分)深部地下環境における炭素鋼の腐食モニタリング―

共焦点レーザー顕微鏡を用いたマイクロ電気化学計測システムによる炭素鋼の孔食発生挙動の観察

門脇 万里子, 武藤 泉, 菅原 優, 原 信義

pp. 497-501

抄録

A microelectrochemical system equipped with a confocal laser scanning microscopy was applied to the real-time observation of pit initiation in the pearlite structure of carbon steel. By using this system, high-resolution images of pit initiation process could be obtained. It was revealed that the initiation site of pitting was in a ferrite lamella, and the pit propagated along the lamellar structure. The cementite remained in the very early stage of pitting.

ブックマーク

SNSによる共有

論文タイトル

共焦点レーザー顕微鏡を用いたマイクロ電気化学計測システムによる炭素鋼の孔食発生挙動の観察

ターフェル外挿法(サイプ法)による中性水溶液中鋼材の腐食速度測定の適用性検討

山本 悟, 小嶋 栄作, 阿部 健, 田代 賢吉

pp. 502-506

抄録

It is important to monitor the corrosion rates of steel in electrolyte environments such as aqueous solution or soil in order to evaluate the integrity of the members of facilities. As a corrosion rate monitoring method, CIPE (Current Interrupted Polarizing Extrapolation) method was developed. By CIPE method the corrosion rate is calculated by the Tafel equation obtained from the polarization curve of the in-situ measurement. In this paper, in order to evaluate accuracy of the method, the measured corrosion rates were compared with the values calculated from mass losses of steel specimens in neutral aqueous solutions of various oxygen supplying conditions. As a result, the actual corrosion mass losses gave good agreement with the values of coulomb amounts which were calculated from the corrosion rates monitored by CIPE. Therefore it is clear that CIPE is an applicable method to real-time monitoring of corrosion rate of steel in aqueous solution. Furthermore, it was found that the corrosion rates which were limited by the oxygen diffusion rates could be measured by CIPE method.

ブックマーク

SNSによる共有

論文タイトル

ターフェル外挿法(サイプ法)による中性水溶液中鋼材の腐食速度測定の適用性検討

Al-Si合金を溶射した鋼板の皮膜欠陥部におけるさび層の電極反応抵抗と皮膜の密着強度

前田 貴俊, 井上 博之, 足立 振一郎, 中山 元, 押川 渡

pp. 507-512

抄録

We considered the corrosion of a steel base at the through coating defective of thermal-sprayed aluminum(TAS) would be suppressed by adding Si to an Al spray material. The steel plate specimens that were thermally spray coated with Al-5Si or Al-12Si and were machined a disk-shaped artificial defect down to the base steel were prepared. For the sake of comparison, the specimens coated with the two types of Al with different purities or Al-5Mg were also prepared in a same manner. After subjecting to outdoor exposure in Okinawa, the charge transfer resistance at an interface between the rust layer and the base steel in the defective part was investigated by EIS. The charge transfer resistance at the interface for the specimen coated with the Al-5Si or the Al-12Si was higher than that coated with the Al or the Al-5Mg. It was estimated that the highly protective rust layers were formed by the action of Si and Al leaching from the coatings by atmospheric corrosion. The thermal spray coating of the Al-5Si and the Al-12Si was superior than that of the Al and the Al-5Mg in the respect of the tensile adhesive strength to the base steel.

ブックマーク

SNSによる共有

論文タイトル

Al-Si合金を溶射した鋼板の皮膜欠陥部におけるさび層の電極反応抵抗と皮膜の密着強度

エンジンルームに搭載される筐体構造電子機器のS8ガスによる硫黄腐食促進試験方法の提案

阿部 博幸, 保川 彰夫, 南谷 林太郎, 齋藤 博之

pp. 513-518

抄録

We studied a highly accelerated corrosion test method for in-vehicle electronic modules. In the module, a circuit board on which the silver wiring was formed was stored in a casing sealed with silicone. SO2, H2S, S8 gas tests were conducted under the condition of 3300 ppm/90℃/80%RH in SO2 test, 60 ppm/90℃/80%RH in H2S test, and 4 ppm/90℃/<10%RH in S8 test. As a result of examining the corrosion rate of the silver wiring, it was found that the S8 gas test has the highest rate of corrosion acceleration. High corrosion rate is presumed to be due to high permeability of S8 gas through silicone, in addition to its high corrosion ability to silver. Based on this result, we propose S8 gas test as a sulfur corrosion accelerated test method.

ブックマーク

SNSによる共有

論文タイトル

エンジンルームに搭載される筐体構造電子機器のS8ガスによる硫黄腐食促進試験方法の提案

住宅環境に長期暴露したPbフリーカチオン電着塗装鋼板の腐食挙動

大居 利彦, 荒賀 邦康, 池田 法民, 清水 剛, 鈴木 清隆, 野村 広正, 松本 剛司, 松本 雅充, 元田 慎一

pp. 519-526

抄録

Since there were not so many reports concerning to the corrosion of painted steel in the indoor environment, we conducted long-term exposure test for Pb free cation electrodeposited painted steel sheet, which was widely used for steel industrialized housing, in the indoor environment. Further, observation and evaluation of blister width, red rust width, ratio of red rust area and the maximum corrosion depth were carried out. From results of evaluation and analysis after exposure test, better correlation between the corrosion on and under the paint film became clear, and the possibility of estimation for corrosion expansion and depth under the paint film by observing appearance of corrosion on the paint film was indicated. On the other hand, among the environmental factors, annual average relative humidity and amount of deposited sea salt are considered to influence in the corrosion behavior under the paint film.