材料と環境 Vol. 62 (2013), No. 2
Backnumber
-
Vol. 73 (2024)
-
Vol. 72 (2023)
-
Vol. 71 (2022)
-
Vol. 70 (2021)
-
Vol. 69 (2020)
-
Vol. 68 (2019)
-
Vol. 67 (2018)
-
Vol. 66 (2017)
-
Vol. 65 (2016)
-
Vol. 64 (2015)
-
Vol. 63 (2014)
-
Vol. 62 (2013)
-
Vol. 61 (2012)
-
Vol. 60 (2011)
-
Vol. 59 (2010)
-
Vol. 58 (2009)
-
Vol. 57 (2008)
-
Vol. 56 (2007)
-
Vol. 55 (2006)
-
Vol. 54 (2005)
-
Vol. 53 (2004)
-
Vol. 52 (2003)
-
Vol. 51 (2002)
-
Vol. 50 (2001)
-
Vol. 49 (2000)
-
Vol. 48 (1999)
-
Vol. 47 (1998)
-
Vol. 46 (1997)
-
Vol. 45 (1996)
-
Vol. 44 (1995)
-
Vol. 43 (1994)
-
Vol. 42 (1993)
-
Vol. 41 (1992)
-
Vol. 40 (1991)
キーワードランキング
03 Dec. (Last 30 Days)
材料と環境 Vol. 62 (2013), No. 2
次世代メディアの耐食性に関する検討(1)
馬渕 勝美, 天羽 美奈, Quing Dai, Bruno Marchon
pp. 47-51
DOI:
10.3323/jcorr.62.47抄録
The fabrication of the corrosion-resistant film on the disk by the pretreatment process using benzotriazole (BTA) solution was for the purpose of corrosion resistant improvement of patterned media. The most suitable pretreatment condition that corrosion resistance was improved is 30-minute dipping to a borate solution containing 1.0% BTA added 3% hydrogen peroxide 3%. By using this pretreatment, the corrosion resistance of the Co alloy in the neutral environment was improved more than 20 times. When hydrogen peroxide was not coexist, the degree of corrosion-resistant improvement was small. The corrosion resistance of the record and the layers which constitute a hard disk conducted pretreatment is maintained in 65℃ and 90% RH condition. A nitrogen group derived from BTA giving corrosion resistance is introduced into the disk surface which prepared pretreatment process. The reason that the BTA layer formation promotes by hydrogen peroxide addition was explained by in the HSAB principle.
次世代メディアの耐食性に関する検討(2)
天羽 美奈, 馬渕 勝美, 吉田 博史, Quing Dai, Bruno Marchon
pp. 52-55
DOI:
10.3323/jcorr.62.52抄録
Novel lubricant with corrosion inhibiting benzotriazole groups was designed and synthesized to secure reliability of next generation bit patterned media (BPM). The novel lubricant exhibited excellent anti-corrosion ability compared to those of the conventional lubricants. Furthermore, the novel lubricant could be a good candidate for thermal assisted magnetic recording (TAR) because of its high thermal durability.
定露点型サイクル試験中の1100アルミニウム合金の腐食挙動における付着塩の影響
島田 隆登志, 大谷 良行, 本川 幸翁, 兒島 洋一, 武藤 泉
pp. 56-60
DOI:
10.3323/jcorr.62.56抄録
Effects of deposited salts on corrosion behavior for an 1100 aluminum alloy were investigated by a constant dew point test with NaCl, MgCl2, and CaCl2. In the constant dew point test, corrosion depth of the 1100 aluminum alloy depended on the deposited salts, increasing in the order of MgCl2, CaCl2, and NaCl. On the other hands, in an immersion test, corrosion depth was independent of the cation species in relatively dilute solutions but depended in concentrated solutions. Furthermore, in a polarization measurement, a cathodic reaction strongly depended on the cation species in the concentrated solutions. It is suggested that the deposited salts in the atmospheric corrosion affect not only the time of wetness but also the cathodic reaction around deliquescence relative humidity where concentrated solutions are formed.
ACMセンサーによる沖縄大気暴露環境評価
東 康弘, 阪田 晴三, 澤田 孝, 宮田 恵守
pp. 61-65
DOI:
10.3323/jcorr.62.61抄録
The lifetime of metallic materials used for telecommunication facilities can be estimated using the corrosion rate when the materials are generally corroded. The corrosion rate differs not only due to local weather and/or atmospheric corrosive factors where the material is but also due to whether the material is directly exposed to rain even in the same location. To evaluate the differences in corrosion rates of steel and zinc due to rain exposure, we placed ACM sensors consisting of Fe/Ag-galvanic and Zn/Ag-galvanic couples in Nago city, Okinawa and measured corrosion currents as output of the sensors. The skyward-facing Fe/Ag sensor responded to rainfall quicker and more stably than the groundward-facing Fe/Ag sensor. This suggests that when a stable electrically conductive water layer was formed should affect the evaluation of the corrosion rate. The annual corrosion rate of steel was estimated to be about 0.09 mm/year, which was equivalent to the reported value in Nishihara, also in Okinawa. The corrosion current of the skyward-facing Zn/Ag sensor showed a tendency to decrease gradually. This made it difficult to estimate the corrosion rate of zinc by using the ACM sensor.
Ni2M安定化合金の等温熱時効による組織変化
佐藤 直宏, 堀内 寿晃
pp. 66-69
DOI:
10.3323/jcorr.62.66抄録
It has been recently pointed out that Alloy690 has the potential to become long-range ordering (LRO) of intermetallic compounds such as Ni2M after long-term use in service conditions in nuclear power plants. However, it is quite difficult to experimentally evaluate the influence of the LRO of Ni2M on SCC susceptibility. In the present study, authors developed the Ni2M-stabilized alloy with excessively enhanced phase stability of Ni2M based on the chemical composition of Alloy690. It was isothermally heat treated for up to 10000 h at 500℃ and 550℃. Microstructure observation, X-ray diffraction analysis and Vickers hardness test were subsequently conducted, and the results were compared with those of Alloy690. The Vickers hardness was significantly increased only in the Ni2M-stabilized alloy after isothermal heat treatment over 1000 h at 500℃. The results of TEM analysis suggest that it may be caused by the LRO of Ni2M. The influence of the LRO of Ni2M on SCC susceptibility will be investigated by the samples obtained in the present study.
酸素欠乏地下環境における炭素鋼腐食モデリング
柴田 俊夫, 渡邊 正敏, 谷口 直樹, 清水 亮彦
pp. 70-77
DOI:
10.3323/jcorr.62.70抄録
In the oxygen depleted underground neutral aqueous solution environment, carbon steel reacts with H2O, producing H2 gas and forming corrosion film on the steel surface. Corrosion rate is controlled by diffusion of reaction species through corrosion film. Diffusion constants of some species working in the corrosion process were obtained from literatures. However, no data were found on the diffusion constant of H2O in iron oxides, which were estimated based on an appropriate assumption. Mass transfer model for the corrosion rate was used to simulate the corrosion rate of carbon steel. Liquid phase diffusion model of Fe2+or H2O through pores in the corrosion film and solid phase diffusion model of H2O through corrosion film itself were examined by simulation using the spread sheet of Excel. Change in corrosion current density and corrosion loss with time and pH and temperature dependence of corrosion current density were examined. By comparing simulated results with the experimental data, it was suggested that the solid phase diffusion of H2O in the corrosion film controls the corrosion rate of carbon steel in oxygen depleted environment.
論文アクセスランキング
03 Dec. (Last 30 Days)
-
-
-
-
凝固過程における溶鋼中からAl2O3上へのMnSの晶出挙動
鉄と鋼 早期公開
-
-
Molecular dynamics simulation of viscosity of the CaO, MgO and Al2O3 melts
ISIJ International 早期公開
-
One-Pot Sonochemical Synthesis of Carbon Nano-Onions from Silicon Carbide in Pure Water
MATERIALS TRANSACTIONS Vol.65(2024), No.11
-
Terminal Settling Velocity of Particle in Suspension
ISIJ International 早期公開
-
Reduction and Carburization Behaviors of Iron Oxide Composite with Iron Carbide and Free Carbon
ISIJ International 早期公開
-
Development of a Low-carbon Sintering Process Technology and Its Application to a Pilot-scale Sintering Testing
ISIJ International Vol.64(2024), No.13
この機能はログイン後に利用できます。
下のボタンをクリックしてください。