材料と環境 Vol. 69 (2020), No. 8
Backnumber
-
Vol. 73 (2024)
-
Vol. 72 (2023)
-
Vol. 71 (2022)
-
Vol. 70 (2021)
-
Vol. 69 (2020)
-
Vol. 68 (2019)
-
Vol. 67 (2018)
-
Vol. 66 (2017)
-
Vol. 65 (2016)
-
Vol. 64 (2015)
-
Vol. 63 (2014)
-
Vol. 62 (2013)
-
Vol. 61 (2012)
-
Vol. 60 (2011)
-
Vol. 59 (2010)
-
Vol. 58 (2009)
-
Vol. 57 (2008)
-
Vol. 56 (2007)
-
Vol. 55 (2006)
-
Vol. 54 (2005)
-
Vol. 53 (2004)
-
Vol. 52 (2003)
-
Vol. 51 (2002)
-
Vol. 50 (2001)
-
Vol. 49 (2000)
-
Vol. 48 (1999)
-
Vol. 47 (1998)
-
Vol. 46 (1997)
-
Vol. 45 (1996)
-
Vol. 44 (1995)
-
Vol. 43 (1994)
-
Vol. 42 (1993)
-
Vol. 41 (1992)
-
Vol. 40 (1991)
キーワードランキング
07 Jan. (Last 30 Days)
材料と環境 Vol. 69 (2020), No. 8
乾湿繰り返し環境下における初期の塗膜下腐食現象のその場観察
山本 俊佑, 安藤 聡
pp. 212-220
DOI:
10.3323/jcorr.69.212抄録
It is well known that the types of automotive corrosion can be divided into perforation corrosion and cosmetic corrosion. Although the mechanism of perforation corrosion has been studied extensively, the mechanism of cosmetic corrosion has not yet been clarified. The authors investigated the cosmetic corrosion behavior of cold-rolled steel sheets without galvanizing with an in-situ observation device. After coating the samples by cathodic electrodeposition (ED), the sample surface was scratched with a cutter. Corrosion resistance was evaluated under cyclic corrosion test. It was found that the progress of under-film corrosion consisted of 3 steps. The 1st step occurs in the initial stage of the dry process in the 1st cycle. In this step, red rust gradually changed to black rust. The 2nd step occurs in the latter stage of the dry process, and under-film corrosion progressed from the scribed part. The 3rd step occurs in the wet process, and in this step, the tip of the under-film corrosion displayed swelling behavior. In the 2nd cycle, the 2nd step and 3rd step of the 1st cycle were repeated. Under-film corrosion progressed at almost the same rate as in the 1st cycle.
ICP-MSと組み合わせた溶液フローセルによる白金およびパラジウム溶解速度の時間分解測定
大井 梓, 多田 英司, 西方 篤
pp. 221-230
DOI:
10.3323/jcorr.69.221抄録
Time-resolved measurement system, consisting of the combination of a commercially available solution-flow cell and an inductively coupled plasma mass spectrometry, for the dissolution rate of platinum (Pt) and palladium (Pd) has been established in this study. A detection limit of the system was successfully improved by thinning the cell channel, and their limits for Pt and Pd were 0.13 pg cm-2 s-1 and 0.39 pg cm-2 s-1, respectively. When the system was applied to Pt and Pd under potential cycling mimicking start/stop condition in polymer electrolyte fuel cell (PEFC), it was revealed that the dissolution of Pt and Pd started from the more negative potential reported in previous studies. Besides, we succeeded in the time-resolved measurement of Pt and Pd dissolution rates below open circuit potential for PEFC (ca. 1.0 V) and clarified that the dissolution mechanisms of Pt and Pd are different.
論文アクセスランキング
07 Jan. (Last 30 Days)
-
Wettability of CaS against molten iron at 1873 K
ISIJ International 早期公開
-
Reduction and Melting Behaviors of Iron Oxide Composite with Carbon Deposited Using CO–CO2–H2 Mixed Gas
ISIJ International Vol.64(2024), No.15
-
凝固過程における溶鋼中からAl2O3上へのMnSの晶出挙動
鉄と鋼 早期公開
-
-
モデル材料を用いた凝固過程における介在物生成挙動のその場観察
鉄と鋼 早期公開
-
-
Effect of Cooling Rate on Microstructure, Phases, and Properties of Al-Si Coated Hot-Press-Forming Steel Sheets
MATERIALS TRANSACTIONS Vol.66(2025), No.1
-
-
Effect of Heating Rate on the Non-Isothermal Hydrogen Reduction of Hematite Pellets
ISIJ International 早期公開
-
この機能はログイン後に利用できます。
下のボタンをクリックしてください。