CTF圧損解析用シミュレータの開発
笹津 浩司, 三沢 信博, 作野 慎一, 村田 勝哉
pp. 264-273
DOI:
10.3775/jie.80.264抄録
The full scale ceramic tube filter (CTF) for hot gas cleaning installed in the 71MWe PFBC combined cycle power plant was successfully demonstrated to establish extremely low emission and stable pressure drop.The pressure drop across both the filter element and the ash accumulated on its surface was analyzed and predicted based on the actual PFBC plant operation data. The equivalent electric circuit model for the flue gas system of the actual PFBC including CTF was built in the simulation program where the characteristic equations were set up to describe the pressure drop across filters. Then the dynamic simulator was constructed and tuned in order to follow the actual plant behaviors.
The reverse cleaning is a very important control factor for the stable operation of CTF. There are four parameters to determine the reverse cleaning conditions: fast pulse cleaning valve open time, pulse cleaning pressure, pulse cleaning interval and pulse cleaning mode. The former two parameters were fixed, while the latter two were controllable.
The optimum condition to satisfy both the lowest maximum pressure drop across CTF and the smallest range of pressure drop variation was explored using the developed simulator. In our case, the three compartments for each CTF vessel were equipped. Then the mode of uniform cleaning against the compartments was suggested as the optimum cleaning one. Such an optimization can be performed exclusively by the simulator, because of too much complexity due to the interaction among the compartments in the actual plant operation.
The possible improvement for the characteristic equations and its corresponding equivalent circuit model were discussed, to allow its application for the commercial plant design.
他の人はこちらも検索
日本エネルギー学会誌 Vol.80(2001), No.11
日本エネルギー学会誌 Vol.80(2001), No.9
日本エネルギー学会誌 Vol.80(2001), No.3